src/onset/onset.c: improve specflux parameters
Experiments using Sebastian Böck database of 27770 onsets (1h42m) [1],
showed that adding compression and adaptive-whitening always
out-performs the raw spectral flux function.
Using shorter windows affects overall results, but decreases the delay.
With the following parameters:
threshold=0.05 win_s=2048 hop_s=1024 novelty=specflux delay_ms=26.6
Strict accuracy / onset: F 75.184 | P 82.478 | R 69.075 | F3 70.216
mir_eval accuracy / file: F 73.749 | P 81.078 | R 71.662 | F3 72.504
Deviation (ms) δ -0.314 | σ 15.396 | δ. 10.89 | σ. 10.88
Total onsets in database: # 27770 | OK 19182 | FP 4075 |
threshold=0.18 win_s=512 hop_s=256 novelty=specflux delay_ms=13.3
Strict accuracy / onset: F 73.200 | P 74.419 | R 72.020 | F3 72.253
mir_eval accuracy / file: F 71.674 | P 76.937 | R 73.973 | F3 74.259
Deviation (ms) δ -0.576 | σ 17.521 | δ. 13.44 | σ. 11.25
Total onsets in database: # 27770 | OK 20000 | FP 6875 |
Note that, unlike in [1], onsets are not combined before evaluation.
[1] Evaluating the online capabilities of onset detection methods,
Sebastian Böck, Florian Krebs and Markus Schedl (ISMIR 2012)